SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Journal of Oncology Pharmacy Practice
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Beaupin, C. M.
Right arrow Articles by Darmanaden, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Beaupin, C. M.
Right arrow Articles by Darmanaden, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Quality control in a centralized reconstitution unit of cytotoxic agents: Determination of etoposide using high-performance thin-layer chromatography

Cécile M. Beaupin

Pharmacy Service, Arnaud de Villenuve Hospital Medical Center, Montpellier, France

Roland Darmanaden

Therapeutical Chemistry, Faculty of Pharmacy, University of Montpellier I, Montpellier, France, Unit of Toxicology in Biochemistry Department of Lapeyronie Hospital Medical Center, Montpellier, France

Introduction. The introduction of a Quality Assur ance Program in the Centralized Reconstitution of Cytotoxic Drugs Unit (CRCDU) at the Arnaud de Villeneuve Hospital Medical Center of Montpellier (France) led to revising our procedures and guide lines. On the average, 170 cytotoxic agents are pre pared weekly, including 20 to 30 preparations of ETOPOSIDE (VP 16). As a quality indicator, we chose etoposide concentration in the final product prepara tion because this drug is viscous and homogenizes poorly in solution. We therefore assumed that etopo side preparation quality should reveal good manufac turing guideline compliance.

Methods. A High-Performance Thin Layer Chro matography (HPTLC) method was selected because it's simple, results can be obtained rapidly, and does not require destruction of a whole preparation. Con centrations were determined by a technique using Silica gel plates (MERCK 60 F 254). Migration solvent was composed of ethyl acetate, methanol, dichloro methane, and aqueous ammonia (170:30:20:10). An optical scanning photodensitometer was set at 220 nm. Each sample was determined in duplicate. Devi ations between theoretical and actual doses were evaluated in terms of pharmaceutical quality related with clinical significance. Results are discussed weekly to determine whether guidelines are consis tent or if a change is necessary.

Results. Eighteen months after implementing, this procedure, its viability as a quality control was tested. 75.9% of samples showed less than 10 percent deviation from theoretical dosage concentration and this is considered a clinically tolerated error by the physicians of our hospital.

Conclusion. In consequence, we feel that using this method is an appropriate quality indicator.

Key Words: Etoposide • quality assurance; CCM dosage.

Journal of Oncology Pharmacy Practice, Vol. 2, No. 1, 35-41 (1996)
DOI: 10.1177/107815529600200105


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement