Journal of Oncology Pharmacy Practice

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for more information

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ackermann, M.
Right arrow Articles by Bonnabry, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ackermann, M.
Right arrow Articles by Bonnabry, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Journal of Oncology Pharmacy Practice, Vol. 13, No. 2, 77-84 (2007)
DOI: 10.1177/1078155207078349
© 2007 SAGE Publications

Evaluation of the design and reliability of three elastomeric and one mechanical infusers

Monique Ackermann

Pharmacy, University Hospitals of Geneva, Switzerland,Monique.Ackermann{at}hcuge.ch

Stéphanie Maier

Pharmacy, University Hospitals of Geneva, Switzerland

Ho Ing

Pharmacy, University Hospitals of Geneva, Switzerland

Pascal Bonnabry

Pharmacy, University Hospitals of Geneva, Switzerland

Background. Disposable elastomeric and mechanical (spring mechanism) infusers with pre-fixed flow rates are principally used for long-term antibiotic therapy, chemotherapy, antiviral therapy, and chronic pain management.

Methods. Three elastomeric pumps and one mechanical infuser pump are evaluated. The design and function are assessed using specific questionnaires elaborated for the pharmaceutical staff, nurses and patients, respectively. Several tests are performed to determine the flow accuracy and the influence of different parameters such as the temperature, the viscosity, the height, and the restrictor variability.

Results. The functional tests show that the perfusion duration is shorter than that specified by the manufacturers, the restrictors are not homogeneous within a batch. However, the temperature of the regulator, the viscosity of the solution, and the height of the reservoir influence the flow rate.

Conclusions. The ideal infuser should be small, light, unnoticeable, easy to fill, well identified and have a flow rate barely affected by external factors. None of the infusers has fulfilled all criteria, therefore the choice of infusers depends upon the nature of the treatment. The tested elastomeric infusers are adequate for 5-fluorouracil, but not for a treatment requiring a stable administration rate.

Key Words: infusers; pumps • elastomeric devices • continuous infusion • chemotherapy • portable infusion device


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?