SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Journal of Oncology Pharmacy Practice
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Kaiser, J.
Right arrow Articles by Krämer, I.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaiser, J.
Right arrow Articles by Krämer, I.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

Stability of irinotecan-loaded drug eluting beads (DC BeadTM) used for transarterial chemoembolisation

Jeanette Kaiser1, Judith Thiesen2, and Irene Krämer3*

1 Johannes Gutenberg-University Hospital
2 Department of Pharmacy, Johannes Gutenberg-University Hospital,
3 Department of Pharmacy, Johannes Gutenberg-University Hospital

* To whom correspondence should be addressed. E-mail: kraemer{at}apotheke.klinik.uni-mainz.de.


   Abstract

Purpose. The aim of this study was to determine the loading efficiency, physicochemical stability, and release of irinotecan-loaded DC BeadsTM (bead size 100–300 µm, 300–500 µm) before and after mixing with nonionic contrast medium (Accupaque® 300, Imeron® 300, Ultravist® 300) during a prolonged period of time (28 days) when stored at room temperature or refrigerated.

Methods. DC BeadsTM were loaded with 50 mg irinotecan (Campto®) per milliliter beads in a 2 h loading period. Drug loading efficiency and stability were determined by measuring the irinotecan concentration in the excess solution. A free-flowing in vitro elution method for a period of 2 h and phosphate buffered solution (PBS, pH 7.2) as elution medium were used to analyze the integrity of the irinotecan-loaded. Stability of irinotecan-loaded beads after mixing with an equal volume of three different nonionic contrast agents was determined by measuring irinotecan concentrations in the excess solutions. Vials with loaded beads were stored protected from light at room temperature. Mixtures with contrast media were stored protected from light under refrigeration (2–8°C). Samples were taken periodically over a 4 week period (day 0, 1, 3, 7 and 28). A reversed phase HPLC assay with ultraviolet detection was utilized to analyze the concentration and purity of irinotecan.

Results. The loading procedure of DC BeadsTM with irinotecan drug solution resulted in a loading percentage of 96% (bead size 100–300 µm) independent of the storage time. No differences in loading levels and no irinotecan degradation products were observed over the period of 28 days, while the test vials were stored light protected at room temperature. Integrity of loaded irinotecan was also given over that same period of time according to the purity and concentration of irinotecan measured after intentional elution with PBS. Mixing of irinotecan-loaded beads (bead size 100–300 µm, 300–500 µm) with nonionic contrast media decreased the irinotecan loading efficiency by ~5–10% during a maximum period of 24 h. However, no further elution or degradation was observed during a 4-week period when stored protected from light under refrigeration.

Conclusions. Irinotecan-loaded DC BeadsTM are shown to have adequate physicochemical stability over a period of at least 28 days when stored light protected at room temperature. Due to concerns of microbiological overgrowth refrigeration should always be considered. The preparation of admixtures of irinotecan-loaded beads with contrast medium in centralized cytotoxic preparation units is not recommended, because of rapid elution of 5–10% of irinotecan from the loaded beads. Furthermore, physicians see no advantages of admixtures due to the wide variation of mixing ratios of drug-loaded beads with contrast medium. In addition varying volumes of 0.9% sodium chloride solution are to be admixed during the chemoembolization procedure.

First published on July 17, 2009
Journal of Oncology Pharmacy Practice 2009, doi:10.1177/1078155209337650


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement